7/13/2007

Measurement Principles

Here are measurement principles of air ions.

(1) Ebert's Ion Counter
This is the first invented ion counter.



[Fig.1 General idea of Ebert ion counter]


A is a cylindrical conductor and it is connected to the ground. B is insulated and coaxial with A. E is a Wolf bipolar electrometer and it is connected to the bottom end of B. The fan on the right bottom part of this image inhales air at the rate of ω/s.

When air passes through between A and B, which is charged at V0, B absorbs oppositely charged ions to neutralize itself.

When V0 reaches Vt and the value of the capacitance of A-B-E is C,
neutralized ions by B is:
C(Vt-V0)
Air ions are measured in pcs/cc.
n, the air ion count, can be given by:
n = C(Vt-V0) / eω --- 1
(e: electricity possessed by a single ion molecule)
The above formula #1 is applicable to air ions with any mobility value.

With higher voltages of A-B and lower flow rates, you can measure the total count of small and large ions (n+N). Therefore, N, the large ion count, can be calculated by (n+N) - n.

(2) Gerdien Condenser
This was developed by applying the principle of the Ebert's Ion Counter. Most ion counters on the market incorporate this technology.

The parallel flat plate type ion counter was developed based on this condenser.


[Fig.2 General idea of Gerdien Condenser]


The Fig.2 shows a dual coaxial cylinder. Air flows in the direction of the arrows.

ro = ID of outer cylinder
ri = Radius of inner cylinder
L = Length of cylinder
Φ = Flow rate per second
V = Voltage applied to outer cylinder

Air ions flow into the inner cylinder according to the electronic field in the dual coaxial cylinder. You can measure the number of positive/negative ions when V is positive/negative respectively.

If all air ions have the same mobility value and all of those entering from P are captured at S, they are all captured by the inner cylinder.

In reality, mobility values of ions are various.
kc, the mobility value of the ion captured at T, is defined as the critical point of mobility value, and it is given by:

kc =Φln(ro/ri)=Φ
2πLV4πaV
a =L
2πln(ro/ri)
Ions which have higher mobility values than the critical point are all captured. Those which have lower values are not captured and they flow out of the cylinder (C). If ions that reach T (see Fig.2) enter from R (D), ions that pass through P-R flow out, and only those which pass through R-Q (shown with oblique lines) are captured in the inner cylinder. The flow rate ratio of the points of φ (area with oblique lines) and Φ (whole entrance area) is given by:
φ/Φ = k/kc
(Reference: Misaki, 1960).



[[Fig.3 Voltage/Current Characteristic Curve of Gerdien Condenser (Misaki, 1976)]

To make it simple, let's assume that only small ions exist and the flow rate is fixed. P on the characteristic curveshows that i has reached the saturation point where small ions are all captured and kc, the critical point of mobility value, is equal to ks, the minimum mobility value of the small ions. Vs, the applied voltage, and ns, the small ion density,are given by:
Vs =Φ
4πaks
ns =is
eΦ

(e=4.77X10-10C, is: Saturated current)

(Reference: Atmospheric Electronic by Shinichiro Kitagawa)


Ion Trading
Digital Air Ion Counter, Good for R&D and product promotion!
Easy operation, Light Weight & Compact design, Many functions. Show in graph form, Data storage!

7/12/2007

Importance of Mobility

Small air ions have more positive effects on the human body. Large air ions have more capabilities to purify the air.

When you study an ionization tendency you need to focus on small or large ions only.
This is important when you compare it with ionization tendencies of other locations.

Every ion molecule possesses its unique mobility value. It is one of the most important factors to decide on which mobility value (i.e. which ion) to focus on.

Ion Trading
Digital Air Ion Counter, Good for R&D and product promotion!
Easy operation, Light Weight & Compact design, Many functions. Show in graph form, Data storage!

Practical measurement of air ions

(1) Both ion counts measurement
Generally, both positive/negative ion counts change every second in the atmosphere. The ratio of positive and negative ions is a very important factor to understand an ionization tendency. Thus it is ideal to measure both positive/negative ion counts.

(2) Simultaneous measurement of both ions
Simultaneous measurement of both ions provides more reliable data.

Ion Trading
Digital Air Ion Counter, Good for R&D and product promotion!
Easy operation, Light Weight & Compact design, Many functions. Show in graph form, Data storage!

Significance of Measurement

(1) Environmental evaluation
A quantitative understanding of ionization tendencies in various locations is one effective way for environmental evaluation.

(2) Evaluation of negative ion products
Before you purchase a negative ion generator (ionizer) it is necessary to know the amount of negative ions it generates. In terms of positive effects on the human body, the amount of small ions detected in the atmosphere is an important factor.

Ion Trading
Digital Air Ion Counter, Good for R&D and product promotion!
Easy operation, Light Weight & Compact design, Many functions. Show in graph form, Data storage!

Summary of tourmaline

Birthstone for October with positive effects on the environment and health.
Beautiful tourmaline necklace Tourmaline (also known as Electronic Stone) is mined in many parts of the world including Brazil, Afghanistan, East Africa and the United States. It is the birthstone for October and has a wide variety of colors. Recently, it has become known that its electronic and chemical properties have significant positive effects on the environment and health.

Its unique crystal structure provides the following features.

1. Generates negative ions
2. Emits infrared rays

Ion Trading
Colorful and High quality Tourmaline bracelets
Negative ions generated by the high quality tourmaline have positive effects on health. Easy to put on and take off!

Beneficial effects of tourmaline

Painkilling, relaxation enhancement, thermal effects, air and water purification, etc.
It is believed that tourmaline has some positive effects:
  • Treatment and prevention of various disease
  • Enhancement of relaxation
  • Thermal effects
  • Air purification
  • Improvement of water/soil quality
Ion Trading
Tourmaline-eRing-long
"I fall asleep better!", "I can have a good sleep!", Many happy users! Generates negative ions without external force!

Applications of tourmaline

Negative ion generation, thermal effects, changing water quality, etc.
1. Negative ion generation
Tourmaline continues to generate negative ions forever and it can be used for improving health and the environment. Negative ions not only have positive effects on the human body but also purify the air.

External energy such as applying pressure or changing temperature is needed to activate the generation of negative ions because tourmaline generates very little amount of negative ions when not in motion or under uniform temperature conditions.

2. Thermal effects
Tourmaline bedclothes can make your body feel warm as infrared rays are emitted.

This quality is utilized to melt snow in areas affected by heavy snowfall.

3. Changing water quality
Water tastes better when mixed with tourmaline stones. Your skin glows after you immerse yourself in water mixed with tourmaline powder. It has not been fully analyzed how these effects occur but it is believed to be caused by mineral elements contained in this miracle stone.

Ion Trading
Tourmaline-eRing-long